This project, in the area of reinforced concrete corrosion, evaluated the potential of half-cell AISI 1018 CS (Carbon Steel) and GS Steel (Steel with galvanized coating); 15 cm long bars were used as reinforcement in specimens of concrete buried in a Type SP Sand (contaminated with 0% and 3% MgSO4). The experimental arrangement of this research represents the case of the elements of the foundations of concrete structures that are planted near marine areas where this type of soil exists with the presence of high contents of depassivating ions such as sulfates. The study specimens were made with two concrete mixtures with a water/cement ratio 0.45 but with different types of cement (Portland Cement and Sulfate Resistant Cement). For monitoring the half-cell potential according to ASTM C 876-15, the specimens were buried in the clean SP soil and in the same soil but contaminated with MgSO4. After more than 270 days of exposure to uncontaminated SP sand contaminated with MgSO4, the behavior of the half-cell potentials or corrosion potentials show that the specimen made with the sulfate-resistant cement and reinforced with GS Steel (Steel with galvanized coating) presents the highest resistance to corrosion by MgSO4 at a concentration of 3%.

Downloads

Download data is not yet available.

Introduction

As indicated by various investigations worldwide, chloride ions are the main aggressive agents causing severe damage due to corrosion of reinforcing steel in infrastructure built with reinforced concrete, damage that can be estimated at billions of dollars only in the USA [1], [2]. In Mexico, there is no information on the real cost of the problem of corrosion of reinforcing steel present in Civil Infrastructure Works. However, the Gulf of Mexico is considered the most corrosive environment. Therefore, the studies that try to contribute to reducing this problem are currently numerous [3]–[5].

The corrosion of reinforcing steel is an electrochemical process, and according to the literature, it is mainly due to the interaction of concrete structures with the environment where they were built, which may contain aggressive agents that may be present in the atmosphere. such as CO2 or aggressive ions (Sulphates and Chlorides), but there is also the possibility that the concrete mixture contains these agents since its preparation or manufacturing [6]–[9]. The elements of reinforced concrete structures that are most susceptible to interacting with sulfates are the foundations, such as foundation slabs, continuous or isolated footings, bridge piers, etc. The above is due to the fact that the presence of sulfates is more frequent in the subsoil and in areas near the coasts. When the concrete element comes into contact with the sulfates, the attack on the concrete matrix begins, causing its degradation. which will lead to the entry of catalyst agents that will depassivate the reinforcing steel [10]–[14]. Sulphate ions as aggressive agents that promote corrosion of reinforcing steel have been a reason to evaluate alternative steels to AISI 1018 steel, so according to results obtained in sulfate corrosion studies, Galvanized Steel has proven to be a viable option when it presents greater resistance than conventional steel [15]–[17].

The use of pozzolanic materials, whether natural or from industrial or agro-industrial waste, for the manufacture of sustainable concrete that improves or provides more protection against corrosion of reinforcing steel caused by aggressive ions such as sulfates has resulted in multiple restoration works. Research has shown promising results when using rice husk ash, sugar cane bagasse ash, metakaolin, and fly ash, among others [18]–[23].

However, all the information cited from multiple investigations previously in this paper has only provided and the variables minimal information related to the mechanism that occurs in the corrosion of the foundation element when in contact with a sulfated environment. Thus, the importance of studying this process using GS Steel (Steel with galvanized coating and and manufactured concrete mixtures with sulfate-resistant cement as a way to mitigate the potential deterioration of reinforced concrete structures reinforced that are in contact with this environment has considerable merit, considering that, more than 95% of the reinforced concrete structures have foundational that will always be in contact with soils that can potentially undermine the integrity of the structure itself.

Materials and Methods

Materials

Design and Proportioning of Concrete Mixture

It was considered for this research project a concrete of f´c = 350 kg/cm2, Normal Cement and Sulfate Resistant Cement, bars of AISI 1018 CS (Carbon Steel) and GS Steel (Steel with galvanized coating), buried in sea sand with the presence of MgSO4 at 0% and 3%. The monitoring the half-cell potential or evaluation of the corrosion potentials (Ecorr) based on ASTM C-876-15 [24].

The ACI 211.1 method was used to carry out the proportioning for the study mixtures for compressive strength at 28 days of 350 kg/cm2 [25]. The quantities of each material are summarized in Table I.

Materials kg
Cement 456
Water 205
Coarse aggregate 995
Fine aggregate 562
Table I. Dosage of the Concrete Mixture for m3

Methods

Characteristics and Specifications of Specimens

The characteristics of the specimens and the reinforcing steels used to monitor the half-cell potential are seen in Fig. 1.

Fig. 1. Specimens for half-cell potential evaluation (characteristics).

The AISI 1018 CS (Carbon Steel) and GS Steel (Steel with galvanized coating) steel bars were previously cleaned as indicated by the scientific community, in addition to leaving an area susceptible to corrosion, as seen in Fig. 2 [26].

Fig. 2. Bars of AISI 1018 CS and GS steel.

The preparation of the study specimens was carried out based on the standard NMX-C-159-2004 [27]. For the correct analysis of the results of the half-cell potential monitoring and according to the variables, the nomenclature presented in Table II was used.

Soil with 0% MgSO4 Soil with 3% of MgSO4
Control medium Agressive medium
CM-GS-PC CM-CS-PC AM-GS-PC AM-CS-PC
CM-GS-SRC CM-CS-SRC AM-GS-SRC AM-CS-SRC
Table II. Nomenclature (Half-Cell Potential Monitoring)

The meaning of the abbreviations used in Table II is as follows:

  • CM: Control Medium,
  • AM: Agressive Medium,
  • GS: Steel with galvanized coating,
  • CS: AISI 1018 Carbon Steel,
  • PC: Porland Cement,
  • SRC: Sulfate Resistant Cement.

The soil used in the present study was obtained from the beach located in the Gulf Mexican, and according to the geotechnical laboratory tests, the soil is classified as poorly graded sand with the symbol SP according to the USCS [28]. Subsequently, containers of considerable size were chosen where the specimens buried in the SP sand with 0% and 3% of MgSO4 as an aggressive agent were placed, see Fig. 3.

Fig. 3. Specimens in their environment of exposure.

Results and Discussion

Corrosion Potential (Ecorr)

The analysis of the behavior of the half-cell potentials of the study specimens in the two exposure media was carried out based on what was established by ASTM C-876-15 more the severe corrosion range [29], see Table III.

Corrosion potentials mV vs. Cu/CuSO4
<−500 Severe corrosion
<−350 90% probability of corrosion
−350 to −200 Uncertainty of corrosion
>−200 10% probability of corrosion
Table III. Corrosion Potential in Reinforced Concrete (Ecorr)

The experimental arrangement to evaluate the effect of the presence of aggressive agents such as sulfates in soils and its relationship with the corrosion of reinforcing steel proposed in this research agrees with what has been carried out by the scientific community worldwide [30]–[32].

The Fig. 4 shows the analysis of the behaviour the half-cell or corrosion potentials, Ecorr, of all specimens buried in SP sand with 0% MgSO4, CM-CS-PC, CM-CS-SRC, CM-GS-PC, CM-GS-SRC. The specimens CM-CS-PC, and CM-CS-SRC, reinforced with AISI 1018 steel, present Ecorr values of −205 to 196 mV in the first monitoring to continue at more positive values reaching more positive values than −100 mV for day 28, behavior due to densification of the concrete matrix in its curing stage, no influence of the type of cement used on the half-cell potential values is identified. However, when the specimens are buried in SP type sand, the CM-CS-SRC specimen has values half-cell potential of between −320 mV to −114 mV after the curing stage until day 84, to remain in a stable range of between −105 to −60 mV until day 160, around −200 mV until on day 238, which would indicate, according to the ASTM C 876-15 standard, a probability of 10% of corrosion, presenting for the last 30 days values more negative than −200 mV associated with corrosion uncertainty.

Fig. 4. Ecorr, specimens in SP sand with 0% of MgSO4.

For the CM-CS-PC specimen, Ecorr values are reported in a range of −295 to −215 mV from the end of the curing stage until day 161 of monitoring, which, according to the standard, would be associated with a corrosion uncertainty, however for The period from day 168 to the end of monitoring reports instability in the half-cell or corrosion potentials Ecorr with values of −540 mV on day 189, to maintain values between −350 to −500 mV until the end of the monitoring. Monitoring, which would indicate a 90% probability of corrosion according to ASTM C-876-15. Better behavior against corrosion of the specimen CM-CS-SRC is observed, this effect is due to the type of sulfate-resistant cement.

In reference to the specimens CM-GS-PC, CM-GS-SRC present half-cell potentials or corrosion potentials, Ecorr, of −740 and −650 mV for the specimens with Portland cement and sulfate-resistant cement, respectively, at the beginning of the monitoring, to reach values more positive than −500 mV at the end of the monitoring curing stage.

Upon coming into contact with SP type sand, the two specimens present more negative values at −500 mV from day 42 to day 70, which is associated, according to the ASTM C-876-15 standard, with severe corrosion, but with the passage of exposure time, both specimens stabilize at values between −350 to −400 mV from day 168, to culminate with half-cell potential values more positive than −350 mV for the CM-GS-SRC specimen, which indicates a 90% probability of corrosion, and for specimen R values of −430 to −520 mV, which would be interpreted as severe corrosion.

For specimens buried in SP sand type with 3% MgSO4, AM-CS-PC, AM-CS-SRC, AM-GS-PC, AM-GS-SRC, In Fig. 5, it is observed that from the beginning of contact with contaminated sand, the effect or influence of sulfate-resistant cement, presenting these specimens the better performance against corrosion throughout the experimental period, presenting values Ecorr in a range of −100 to −150 mV throughout the monitoring period the specimen AM-CS-SRC indicating a probability of 10%. Instead, the AM-CS-PC specimen presents Ecorr values from the day 50 to 200 observation that indicate uncertainty, to be located in an area of 10% corrosion in the last 70 days. In the case of specimens with GS Steel (Steel with galvanized coating), AM-GS-PC and AM-GS-SRC, also from the 35th day up to the 200th demonstrated the best performance of GS Steel in the concrete made with sulphate-resistant cement with Ecorr values indicating uncertainty in contrast to the elaborate with normal cement presenting values of half-cell potentials or Ecorr more negative than −350 mV, which according to the ASTM C-876-15 standard is associated with a 90% probability that steel corrosion is occurring, results that agree with those reported in the literature [33], [34].

Fig. 5. Ecorr, specimens in SP sand with 3% of MgSO4.

The apparent benefit of sulfated media observed in Fig. 5, or apparent protection against corrosion of reinforcing steel in concrete buried in sulphated sand, only occurs in the first months of contact, according to the literature [35], and is associated with the action of by magnesium sulphate also results in a hard, dense film formed in the concrete due to the deposition of magnesium hydroxide in the pores, and this tends to impede penetration of the solution. This is because the concrete has a lower permeability, and it is very likely that potential and low corrosion rates will result, which could be interpreted as a beneficial effect against corrosion [36].

Conclusions

With this work and according to the results obtained, it has been demonstrated that the type of cement used for the elaboration of concrete exposed to soils in the presence of sulphates influences the electrochemical behaviour of reinforcing steel, galvanized, as well as non-galvanized steel.

Since the demonstration of the efficacy of reinforcing steel in concrete made with sulfate-resistant cement has a better performance compared to reinforcing steel in concrete made with common Portland Cement.

Also, it can be concluded that specimens with galvanized steel as a reinforcing agent present more homogeneous behaviour but, at the same time, a higher probability of corrosion than normal steel specimens.

References

  1. Raczkiewicz W. Use of polypropylene fibres to increase the resistance of reinforcement to chloride corrosion in concretes. Sci Eng Compos Mater. 2021;28(1):555–67. doi: 10.1515/secm-2021-0053.
    DOI  |   Google Scholar
  2. Baltazar-García BP, Baltazar-Zamora DF, Sánchez-Sánchez O, Balderas P, Mendoza-Rngel JM, Gaona-Tiburcio C, et al. Carbonation depth of sustainable concrete made with agroindustrial and industrial waste exposed to the urban environment of the City of Xalapa, Ver; Mexico. Eur J Eng Technol Res. 2023;8(3):48–53. doi: 10.24018/ejeng.2023.8.3.3042.
    DOI  |   Google Scholar
  3. Raczkiewicz W, Bacharz M, Bacharz K, Teodorczyk M. Reinforcement corrosion testing in concrete and fiber reinforced concrete specimens exposed to aggressive external factors. Materi- als. 2023;16(3):1174. doi: 10.3390/ma16031174.
    DOI  |   Google Scholar
  4. Landa-Ruiz L, Croche R, Santiago-Hurtado G, Moreno-Landeros V, Cuevas J, Méndez CT, et al. Evaluation of the influence of the level of corrosion of the reinforcing steel in the moment-curvature diagrams of rectangular concrete columns. Eur J Eng Technol Res. 2021;6(3):139–45. doi: 10.24018/ejeng.2021.6.3.2423.
    DOI  |   Google Scholar
  5. Uthaman S, Vishwakarma V. Assessment of causes and consequences of concrete deterioration and its remediation. J Build Eng. 2023;79:107790. doi: 10.1016/j.jobe.2023.107790.
    DOI  |   Google Scholar
  6. Hassi S, Menu B, Ebn TM. The use of the electrochemical impedance technique to predict the resistance to chloride ingress in silica fume and fly ash-reinforced blended mortars exposed to chloride or chloride-sulfate solutions. J Bio Tribo Corros. 2022;8(1):13. doi: 10.1007/s40735-021-00609-1.
    DOI  |   Google Scholar
  7. Fig. 4. Ecorr, specimens in SP sand with 0% of MgSO4.
     Google Scholar
  8. Baltazar-García BP, Baltazar-Zamora DF, Landa-Ruiz L, Méndez CT, Santiago-Hurtado G, Moreno-Landeros V, et al. Electro-chemical corrosion in bars of AISI 304 embedded in concrete immersed in marine-sulfated environment. Eur J Eng Technol Res. 2023;8(1):13–8. doi: 10.24018/ejeng.2023.8.1.2942.
    DOI  |   Google Scholar
  9. Ormellese M, Berra M, Bolzoni F, Pastore T. Corrosion inhibitors for chlorides induced corrosion in reinforced con- crete structures. Cement Concrete Res. 2006;36(3):536–47. doi: 10.1016/j.cemconres.2005.11.007.
    DOI  |   Google Scholar
  10. Burtuujin G, Son D, Jang I, Yi C, Lee H. Corrosion behavior of pre-rusted rebars in cement mortar exposed to harsh environment. Appl Sci. 2020;10:8705. doi: 10.3390/app10238705.
    DOI  |   Google Scholar
  11. Baltazar-García BP, Baltazar-Zamora DF, Landa-Ruiz L, Méndez CT, Solorzano R, Reyes J, et al. Corrosion behavior of AISI, 1018 reinforcing steel in sustainable concrete made with sugar cane bagasse ash and recycled aggregates exposed in seawater. Eur J Eng Technol Res. 2022;7(6):101–7. doi: 10.24018/ejeng.2022.7.6.2930.
    DOI  |   Google Scholar
  12. Wang D, Zhao X, Meng Y, Chen Z. Durability of concrete con- taining fly ash and silica fume against combined freezing-thawing and sulfate attack. Constr Build Mater. 2017;147:398–406. doi: 10.1016/j.conbuildmat.2017.04.172.
    DOI  |   Google Scholar
  13. Zhang C, Zhu M, Xu K, Yuan Y, Guo S, Wei G. Effect of HSO3− and alternating current on corrosion behaviour and mechanism of CoCrFeNi HEA in a simulated marine environment. Corros Eng Sci Technol. 2023;58:2190443. doi: 10.1080/1478422X.2023.2190443.
    DOI  |   Google Scholar
  14. Landa-Ruiz L, Ariza-Figueroa H, Santiago-Hurtado G, Moreno- Landeros V, López Meraz R, Villegas-Apaez R, et al. Evaluation of the behavior of the physical and mechanical properties of green concrete exposed to magnesium sulfate. Eur J Eng Res Sci. 2020;5(11):1353–6. doi: 10.24018/ejeng.2020.5.11.2241.
    DOI  |   Google Scholar
  15. Sakai T, Inukai S, Inagaki M, Nakano M. Improvement in seis- mic resistance using replacement/counterweight fill method for existing high embankments on inclined ground constructed with various embankment materials. Soils Found. 2023;63(2):1–14. doi: 10.1016/j.sandf.2023.101284.
    DOI  |   Google Scholar
  16. Xu P, Jiang L, Guo M, Zha J, Chen L, Chen C, et al. Influence of sulfate salt type on passive film of steel in simulated concrete pore solution. Constr Build Mater. 2019;223:352–9.
    DOI  |   Google Scholar
  17. Raczkiewicz W, Wójcicki A. Temperature impact on the assessment of reinforcement corrosion risk in concrete by galvanostatic pulse method. Appl Sci. 2020;10(3):1–13. doi: 10.3390/app10031089.
    DOI  |   Google Scholar
  18. Farhangi V, Karakouzian M. Effect of fiber reinforced polymer tubes filled with recycled materials and concrete on structural capacity of pile foundations. Appl Sci. 2020;10:1554. doi: 10.3390/app10051554.
    DOI  |   Google Scholar
  19. Baltazar-Zamora MA, Mendoza-Rangel JM, Croche R, Gaona- Tiburcio C, Hernández C, López L, et al. Corrosion behavior of galvanized steel embedded in concrete exposed to soil type MH contaminated with chlorides. Front Mater. 2019;6:1–12. doi: 10.3389/fmats.2019.00257.
    DOI  |   Google Scholar
  20. Xiao T, Du C, Liu Y. Electrochemical evaluation on corrosion behavior of SAF, 2507 duplex stainless steels in blended concrete with metakaolin and ultrafine slag admixtures. Int J Electrochem Sc. 2021;16:210642. doi: 10.20964/2021.06.15.
    DOI  |   Google Scholar
  21. Landa-Ruiz L, Baltazar-Zamora MB, Bosch J, Ress J, Santiago- Hurtado G, Moreno-Landeros VM, et al. Electrochemical corrosion of galvanized steel in binary sustainable concrete made with sugar Cane Bagasse Ash (SCBA) and Silica Fume (SF) exposed to sulfates. Appl Sci. 2021;11:2133. doi: 10.3390/app11052133.
    DOI  |   Google Scholar
  22. Abdalla T, Elhameed A, Meng Y, Hummaida Y, Semmana O. Strength, durability, and microstructure properties of concrete containing bagasse ash–A review of 15 years of perspectives, progress and future insights. Results in Engineering. 2024;21:101764. doi: 10.1016/j.rineng.2024.101764.
    DOI  |   Google Scholar
  23. Baltazar-Zamora MA, Bastidas DM, Santiago-Hurtado G, Mendoza-Rangel JM, Gaona-Tiburcio C, Bastidas JM, et al. Effect of silica fume and fly ash admixtures on the corrosion behavior of AISI 304 embedded in concrete exposed in 3.5% NaCl solution. Materials (Basel). 2019;12(23):1–13. doi: 10.3390/ma12234007.
    DOI  |   Google Scholar
  24. Baltazar-Zamora MA, Landa-Ruiz L, Landa-Gómez AE, Santiago-Hurtado G, Moreno-Landeros V, Méndez Ramírez CT, et al. Corrosion of AISI 316 stainless steel embedded in green concrete with low volume of sugar cane bagasse ash and silica fume exposed in seawater. Eur J Eng Technol Res. 2022;7(1):57–62. doi: 10.24018/ejeng.2022.7.1.2716.
    DOI  |   Google Scholar
  25. ASTM. ASTM C 876-15, Standard test method for corrosion potentials of uncoated reinforcing steel in concrete. West Conshohocken, PA: ASTM International; 2015. www.astm. org.
     Google Scholar
  26. ACI. Provision of Mixtures, Normal Concrete, Heavy and Massive ACI 211.1. Mexico: Ed. IMCYC; 2004, pp. 29.
     Google Scholar
  27. Landa-Sánchez A, Bosch J, Baltazar-Zamora MA, Croche R, Landa-Ruiz L, Santiago-Hurtado G, et al. Corrosion behavior of steel-reinforced green concrete containing recycled coarse aggregate additions in sulfate media. Materials (Basel). 2020;13(19):1–22. doi: 10.3390/ma13194345.
    DOI  |   Google Scholar
  28. NMX-C-159-ONNCCE-2004: Elaboración y Curado de Especímenes de Ensayo. México: ONNCCE S.C.; 2014.
     Google Scholar
  29. Das B. Principio de Ingeniería de Cimentaciones. Thompson, Ed. México, 2006, pp. 67.
     Google Scholar
  30. Song HW, Saraswathy V. Corrosion monitoring of reinforced concrete structures—a review. Int J Electrochem Sci. 2007;2(1):1–28.
    DOI  |   Google Scholar
  31. Troconis de Rincón O, Montenegro JC, Vera R, Carvajal AM, de Gutiérrez RM, Del Vasto S, et al. Reinforced concrete durability in marine environments DURACON project: long-term exposure. Corrosion. 2016;72(6):824–33. doi: 10.5006/1893.
    DOI  |   Google Scholar
  32. Baltazar-Zamora MA, Ariza-Figueroa H, Landa-Ruiz L, Croche R. Electrochemical evaluation of AISI 304 SS and galvanized steel in ternary ecological concrete based on sugar cane Bagasse Ash and Silica Fume (SCBA-SF) exposed to Na2 SO4 . Eur J Eng Res Sci. 2020;5(3):353–7. doi: 10.24018/ejeng.2020.5.3.1852.
    DOI  |   Google Scholar
  33. Cosoli G, Mobili A, Tittarelli F, Revel GM, Chiariotti P. Electrical resistivity and electrical impedance measurement in mortar and concrete elements: a systematic review. Appl Sci. 2020;10:9152. doi: 10.3390/app10249152.
    DOI  |   Google Scholar
  34. Baltazar-Zamora MA, Maldonado-Bandala E, Loya Tello MU, Santiago-Hurtado G, Olguín Coca FJ, Ortiz-Cedano A, et al. Efficiency of galvanized steel embedded in concrete previously contaminated with 2, 3 and 4% of NaCl. Int J Electrochem Sci. 2012;7(4):2997–3007.
    DOI  |   Google Scholar
  35. Rabi M, Shamass R, Cashell KA. Structural performance of stainless steel reinforced concrete members: a review. Constr Build Mater. 2022;325:126673. doi: 10.1016/j.conbuildmat.2022.126673.
    DOI  |   Google Scholar
  36. Baltazar-García BP, Baltazar-Zamora DF, Landa-Ruiz L, Méndez CT, Solorzano R, Estupiñan López FH, et al. Eco-friendly concrete made with system CPC-SCBA-SF as a protector against sulfate corrosion of reinforcing steel AISI 1018. Eur J Eng Technol Res. 2022;7(6):14–20. doi: 10.24018/ejeng.2022.7.6.2911.
    DOI  |   Google Scholar
  37. Ariza-Figueroa HA, Bosch J, Baltazar-Zamora MA, Croche R, Santiago-Hurtado G, Landa-Ruiz L, et al. Corrosion behav- ior of AISI 304 stainless steel reinforcements in SCBA-SF ternary ecological concrete exposed to MgSO4. Materials (Basel). 2020;13(10):1–16. doi: 10.3390/ma13102412.
    DOI  |   Google Scholar


Most read articles by the same author(s)

1 2 > >>