In the present research, was studied the electrochemical behavior of AISI 304 stainless steel and Galvanized Steel embedded in Ternary Ecological Concrete made with partial substitution of Portland Cement (PC) by combination of Sugar Cane Bagasse Ash and Silica Fume (SCBA-SF) in 10, 20 and 30% and exposed to a 3.5% solution of Na2SO4 as an aggressive medium. For the design of the concrete mixtures was used ACI 211.1 method. Quality control tests of fresh and hardened concrete were carried out in accordance with the ONNCCE and ASTM standards. The electrochemical evaluation was carried out for a period of 6 months, using the techniques of corrosion potential Ecorr (ASTM C-876-15) and Linear Polarization Resistance-LPR- (ASTM G59) to determine the corrosion rate Icorr. The results indicate that AISI 304 SS has a high corrosion resistance from the curing stage to the end of monitoring, with values of Ecorr lower than -200 mV and negligible corrosion levels with values of Icorr below 0.1 µA/cm2, greater protection is identified in the Ternary Ecological Concrete with replacement of 30% of PC by SCBA-SF.