##plugins.themes.bootstrap3.article.main##

Surface electromyography technique is presented for muscle activation detection and intuitive control of prostheses or robot arm. This research aims to develop a strategy for collecting EMG signal in order to be used as input control for an artificial hand. Methodology of this research composed of, collecting EMG signal using clinical device to choose the best position. Collect the signal using myoware muscle sensor depending on these positions locating above with determining the threshold value for each position. The test was done on a healthy female person and an amputee person, a number of three position were used by the clinical myotrace 400 each positon composed of four channels i, four channel location were chosen from the three position that were used by the myoware sensor on the forearm in addition to two locations on the ulna, while the amputee included only two locations on the ulna. The locations obtained from the myotrace targeting muscles ( extensor carpi ulnaris, flexor digitorium sublimis, brachioradialis, flexor carpi ulnaris). The threshold values obtained were on a range of 150-320 that consider a non-sensitive. For the amputee the threshold values were the from 150-220  for both the healthy arm and the amputee arm which consider a weaker values. 

Downloads

Download data is not yet available.

References

  1. S. Guo, M. Pang , B. Gao, H. Hirata and H. Ishihara , "Comparison of sEMG-Based Feature Extraction and Motion Classification Methods for Upper-Limb Movement," sensors , pp. 9023-9037, 2015.
     Google Scholar
  2. M. . B. I. Reaz, M. . S. Hussain and F. Mohd-Yasin, "Techniques of EMG signal analysis: detection, processing, classification and applications," Malaysia , 2006.
     Google Scholar
  3. M. A. Oskoei and H. Hu, "Myoelectric control systems—A survey," Elesvier ,Biomedical Signal Processing and Control, pp. 276-289-290, 2007.
     Google Scholar
  4. F. Tenore, A. Ramos, A. Fahmy, S. Acharya, R. Etienne-Cummings and N. V. Thakor, "Towards the Control of Individual Fingers of a Prosthetic Hand Using Surface EMG Signals," in 29th Annual International Conference of the IEEE EMBS Cité Internationale, Lyon, France, 2007.
     Google Scholar
  5. R. A. R. C. Gopura, K. Kiguchi and E. Horikawa, "A Study on Human Upper-Limb Muscles Activities during Daily Upper-Limb Motions," International Journal of Bioelectromagnetism, vol. 12, no. 2, pp. 54 - 61, 2010.
     Google Scholar
  6. S. N. Sidek, N. A. Jalaludin and A. U. Shamsudin, "Surface Electromyography (sEMG)-based Thumb-tip Angle and Force Estimation Using Artificial Neural Network for Prosthetic Thumb," Elesevier ,Procedia Engineering , pp. 650-656, 2012.
     Google Scholar
  7. J. S. Chiad, B. A. Bdawi and . A. J. Abbed, "Study the Effect of the Foundation Surface on the Vibration Data at the Worker Arm Using Drilling Machine," International Journal of Advanced Sport Sciences Research, pp. 539-547, 2015.
     Google Scholar